Measuring With Light Is Mind Blowing
From New Mind · · 30 min

The player loads from YouTube only when you click. It uses YouTube's privacy-enhanced mode.
If the video does not play, the owner may have turned off embedding. Watch it on YouTube instead.
Description
🎧 Go to https://buyraycon.com/newmindCLIP to get up to 50% off! Thanks to Raycon for sponsoring!
This video traces the evolution of non-contact metrology, from a spider's thread inside a 17th-century telescope to laser interferometers, industrial CT and the optical frequency comb.
THE FIRST ATTEMPTS · A spider's thread in Gascoigne's telescope led to the first micrometer in the late 1630s. · The 1889 Prototype Metre had its defining lines engraved on the bar's neutral plane. · Every standard was a physical object that could wear, drift or be lost.
LIGHT · Michelson's interferometer moved one full fringe for every half wavelength of mirror travel. · A ladder of nine etalons counted 1,553,164 cadmium wavelengths in the metre. · In 1960 the metre was redefined as 1,650,763.73 wavelengths of krypton-86 light.
SHADOW MEASUREMENT · WWI shells and fuses from thousands of contractors needed threads that interchanged. · Vermont governor James Hartness and Russell Porter built a screw thread comparator. · At fifty times magnification, a thousandth-of-an-inch flank error showed as a twentieth of an inch on the screen.
AIR AND FIELD · Air gauging began in late-1920s France as a way to standardize carburetor jets. · Back-pressure behind a nozzle read the gap to the part to fractions of a micron. · Bently's garage-built eddy current probe watched turbine shafts spinning on films of oil.
THE LASER INTERFEROMETER · A stabilized laser kept clear fringes over hundreds of meters, not a fraction of one. · HP's 1970 5525A counted a Doppler-shifted beat frequency instead of beam brightness. · One degree of air temperature shifts the laser's effective wavelength by about one part per million.
MACHINE VISION · The CCD's photolithographed pixels built a precise ruler directly into the silicon. · Cognex's first product, DataMan, read serial numbers on IBM's silicon wafers. · Subpixel edge location found edges to a tenth of a pixel or better.
TRIANGULATION · Meydenbauer named photogrammetry in 1867, after surveying the cathedral at Wetzlar. · Structured light reached consumers through the Kinect and the iPhone's 30,000 projected dots. · Kam Lau's laser tracker began as a retired interferometer on an old rotary table.
INDUSTRIAL X-RAY · Turbine cooling passages and 3D-printed lattices hid features no probe could reach. · Werth's 2005 TomoScope was the first CT machine built for coordinate metrology. · Beam hardening made the centers of thick sections look less dense than they really were.
SURFACE MEASUREMENT · Minsky invented the confocal microscope in 1955 to trace neurons in thick brain tissue. · White-light fringes appear only where the two light paths match to within about a micron. · Scatterometry works out chip features far smaller than Abbe's 200-nanometer limit.
THE FREQUENCY COMB · Hall and Hänsch's comb linked light's trillions of oscillations a second to an atomic clock. · One laser of evenly spaced colors replaced room-sized chains of specialized lasers. · In 2009, NIST used two combs to measure absolute distance without counting fringes.
------ SUPPORT NEW MIND ON PATREON https://www.patreon.com/newmind
SOCIAL MEDIA Instagram - @newmindchannel
#metrology #engineering #precisionengineering #measurement #noncontactmetrology #manufacturing #interferometry #interferometer #Michelson #opticalflat #opticalcomparator #airgauging #eddycurrent #proximityprobe #BentlyNevada #laserinterferometer #HewlettPackard #machinevision #Cognex #CCD #photogrammetry #lasertriangulation #structuredlight #3Dscanning #lasertracker #industrialCT #computedtomography #confocalmicroscopy #whitelightinterferometry #scatterometry #frequencycomb #NIST #qualitycontrol #inspection #engineeringhistory #industrialhistory #historyoftechnology #physics